00971 55 891 6006 info@purelineuae.com
Trusted By
10,000+ People
Best Services
in GCC and Africa
Number #1
Water Treatment Service

Industrial 14000 GPD RO Plant Purification System

Powerful 14,000 GPD industrial RO system built with a durable stainless steel frame for reliable, high-capacity water purification. Features integrated flow meters and pressure gauges to ensure easy monitoring and peak performance for industrial operations.

Description

Introduction:
This high-capacity Industrial 14000 GPD RO Plant is designed for businesses that need a reliable and steady supply of pure water. Capable of producing 14,000 gallons per day (GPD), this system effectively removes impurities, salts, and contaminants, making it ideal for manufacturing, food processing, and large-scale commercial use.


Key Features of 14000 GPD RO Plant:

  • High Output: Produces up to 14,000 gallons of purified water daily to meet heavy industrial demands.

  • Stainless Steel Frame: Built with a durable, corrosion-resistant stainless steel skid for long-lasting performance in tough environments.

  • Advanced Monitoring: Equipped with easy-to-read pressure gauges and flow meters to monitor system health in real-time.

  • Efficient Filtration: Utilizes high-quality membranes to ensure the highest rejection of total dissolved solids (TDS).

  • Compact Design: Engineered to provide maximum output while occupying minimal floor space.


Technical Specifications:

  • Daily Capacity: 14,000 GPD (Gallons Per Day)

  • System Type: Vertical Industrial RO Skid

  • Material: Heavy-duty Stainless Steel

  • Components: High-pressure pump, RO membrane housings, flow meters, and pressure indicators.

Operating Instructions:

  • Check Valves: Open all water supply valves before starting the system.

  • Inspect Lines: Check the blue hoses and stainless steel frame for leaks.

  • Power On: Turn the main switch on the control panel to “ON”.

  • Start Pump: The high-pressure pump will begin pushing water through the system.

  • Check Pressure: Monitor the two circular gauges on the front panel.

  • Verify Flow: Look at the vertical glass flow meters for pure and waste water.

  • Track Output: Ensure the system reaches the 14,000 GPD production target.

  • Watch Display: Check the digital screen for any error alerts during use.

  • Change Filters: Replace the side sediment filters every 1 to 3 months.

  • Power Off: Turn the switch to “OFF” when the water tank is full.

  • Flush System: Perform a manual flush to rinse salts off the membranes.

  • Keep Records: Write down daily pressure and flow readings in a logbook.

  • Stay Clean: Wipe the stainless steel skid to prevent rust or salt buildup.